Treatment method for wear and tear of automatic waste paper baler

        Treatment method for wear and tear of automatic waste paper baler.

        1. Check the operation of the pump. If the small waste paper baler is noisy, the needle swing is large, and the oil temperature is too high, the pump may be severely worn.

        2. Understand the operating efficiency of the pump. Comparing the temperature of the pump casing and the fuel tank, if the temperature difference between the two is higher than 5 degrees Celsius, the pump efficiency can be considered low.

        3. Check the oil leakage of the pump shaft and joints, and pay attention to leakage at high temperature and high pressure.

        4. Observe the indication value of the vacuum gauge installed at the suction pipe of the pump. During normal operation, its value should be below 127mmhg; otherwise, check the oil filter and working oil of the automatic waste paper baler.